  • 落水系统遇堵漏该如何处理?
  • 本站编辑:杭州曼布斯建材有限公司发布日期:2022-01-12 14:41 浏览次数:

彩铝落水系统有良好的耐候性,设计简洁,安装简单,安全耐用。

The color aluminum falling water system has excellent weather resistance, simple design, simple installation, safety and durability.

天沟外排水系统适用于长度不超过l00m的多跨工业厂房。

The drainage system outside the gutter is suitable for multi span industrial plants with a length of no more than l00m.

在寒冷地区,设置天沟时雨水立管也可设在室内。

In cold areas, when gutters are set, rainwater risers can also be set indoors.

屋面天沟防水层施工时,应先做好节点,附加层和屋面排水比较集中等部位的处理。

During the construction of roof gutter waterproof layer, the joint, additional layer and roof drainage shall be treated first.

落水系统如遇到渗漏情况时,可以采取以下措施:

In case of leakage in the water falling system, the following measures can be taken:

铲除旧防水涂层及保温层,挖出旧嵌缝材料;        

Remove the old waterproof coating and thermal insulation layer, and dig out the old caulking material;

清理泛水部位的涂膜防水层,面层应干燥、洁净。

Clean the film waterproof layer at the flashing part, and the surface layer shall be dry and clean.

清理干净后,刮填嵌缝材料,表面做一布二涂加强层。        

After cleaning, the caulking material shall be scraped and filled, and one cloth and two coats of reinforcing layer shall be made on the surface.

泛水部位应增设有胎体增强材料的附加层,涂膜防水层泛水高度不应小于250mm。        

An additional layer of matrix reinforcement shall be added at the flashing part, and the flashing height of the coating waterproof layer shall not be less than 250mm.

天沟、水落口维修时,应清理防水层及基层,天沟应无积水且干燥,水落口应与基层锚固。

During the maintenance of gutter and water outlet, the waterproof layer and base course shall be cleaned, the gutter shall be free of ponding and dry, and the water outlet shall be anchored with the base course.

施工时先做水落口的增强附加层,其直径应比水落口大100mm,铺设涂膜防水层应加铺胎体增强材料。

During construction, the reinforced additional layer of the water outlet shall be made first, and its diameter shall be 100mm larger than the water outlet. The coating waterproof layer shall be paved with matrix reinforcement.